Single-use double-lumen bronchial catheter
Product Features
The tube body is transparent, soft, and smooth, and the distal end of the bronchial catheter is slightly curved, which facilitates accurate placement in either the left or right main bronchus.
The tracheal intubation tube features a smooth, rounded bevel and Murphy’s hole with no sharp edges; the cuff and the tube body transition seamlessly, with a secure, burr-free design that eliminates injury to the tracheal mucosa.
The low-pressure tracheal cuff can minimize trauma to the tracheal tissues.
High-capacity, low-pressure cuff for improved airway sealing;
The indicator sac is synchronized with the airbag, and its inflation status can be determined by observing the indicator sac.
The blue bronchial cuff is designed to assist the fiberoptic bronchoscope in locating the distal catheter.
Full-length X-ray visualization; the catheter tip is marked with an additional radiopaque indicator above the bronchial cuff to facilitate assessment of catheter positioning.
Bilateral endotracheal intubation enables ventilation of the right and left lungs via separate pathways, thereby isolating the affected lung from the healthy one, preventing the spread of secretions and pathogens, and reducing the risk of acute airway obstruction.
A fixed shaping guidewire facilitates insertion into the body.
Model Specification
Dual-lumen 28 left
Dual-lumen 28 right
Dual-lumen 32 left
Dual-lumen 32 right
Dual-lumen 35 left
Dual-lumen 35 right
Dual-lumen 37 left
Dual-lumen 37 right
Dual-lumen 39 left
Dual-lumen 39 right
Product Features
The tube body is transparent, soft, and smooth, and the distal end of the bronchial catheter is slightly curved, which facilitates accurate placement in either the left or right main bronchus.
The tracheal intubation tube features a smooth, rounded bevel and Murphy’s hole with no sharp edges; the cuff and the tube body transition seamlessly, with a secure, burr-free design that eliminates injury to the tracheal mucosa.
The low-pressure tracheal cuff can minimize trauma to the tracheal tissues.
High-capacity, low-pressure cuff for improved airway sealing;
The indicator sac is synchronized with the airbag, and its inflation status can be determined by observing the indicator sac.
The blue bronchial cuff is designed to assist the fiberoptic bronchoscope in locating the distal catheter.
Full-length X-ray visualization; the catheter tip is marked with an additional radiopaque indicator above the bronchial cuff to facilitate assessment of catheter positioning.
Bilateral endotracheal intubation enables ventilation of the right and left lungs via separate pathways, thereby isolating the affected lung from the healthy one, preventing the spread of secretions and pathogens, and reducing the risk of acute airway obstruction.
A fixed shaping guidewire facilitates insertion into the body.
Model Specification
Dual-lumen 28 left
Dual-lumen 28 right
Dual-lumen 32 left
Dual-lumen 32 right
Dual-lumen 35 left
Dual-lumen 35 right
Dual-lumen 37 left
Dual-lumen 37 right
Dual-lumen 39 left
Dual-lumen 39 right
Previous page
Next page
Previous page
Next page